The American Society of Anesthesiologists has prepared recommendations for caring for a patient with known or suspected Covid-19 infection.

Content extracted from ASA Website March 16, 2020: Access webpage by clicking here.


When caring for a patient with known or suspected COVID-191 infection:

  • Place patients in an Airborne Infection Isolation Room2
  • Health care professionals entering the room should use airborne and contact precautions, including eye protection.
  • Personal protective equipment3 (PPE) to be worn includes:
    • Either an N95 mask, for which one has been fit-tested, or a powered air-purifying respirator (PAPR)4.;
    • A face shield or goggles;
    • A gown;
    • Gloves.
  • Hand hygiene is essential before donning and after doffing PPE. Hand hygiene can be performed using alcohol-based hand rubs or hand washing with soap and water. Wash hands with soap and water if hands are visibly soiled.
  • Use extreme caution when removing and disposing of PPE to minimize the risk of self-contamination. Strongly consider observing the correct procedures for donning and doffing PPE and then rehearsing these procedures prior to direct patient care.
  • For further details, refer to the CDC guidance.

When considering a procedure for a patient with known or suspected COVID-19 infection:

  • Postpone non-urgent surgical procedures until the patient is determined to be non-infectious or not infected.
  • If respiratory support is indicated, then planning ahead may avoid the need for rescue interventions (e.g., crash intubations), which have greater potential for infectious transmission due to mishaps during the use of barrier protections.
  • In patient with acute respiratory failure, it may be prudent to proceed directly to endotracheal intubation, because non-invasive ventilation (e.g. CPAP or biPAP) may increase the risk of infectious transmission5.
  • When possible, perform procedures in an airborne infection isolation room rather than in an operating room. An airborne isolation room has a negative-pressure relative to the surrounding area. In contrast, a typical operating room is designed to provide positive-pressure relative to the surrounding area and incoming air is often flow-directed, filtered, and temperature and humidity controlled.
  • If a procedure cannot be postponed or done at the bedside, then schedule the patient when a minimum number of healthcare workers and other patients are present in the surgical suite.
  • Seek collaboration with local infection control expertise.

When patients with known or suspected COVID-19 infection need to be transported:

  • Transport patients only for procedures and studies deemed essential for patient care.
  • Consult local infection control expertise prior to transport.
  • Intubated patients should have a HEPA filter inserted between the bag-valve-mask breathing device and the patient.
  • Patients who are not ventilated should wear a surgical mask.
  • Health care professionals transporting the patient should not routinely wear gowns and gloves, unless direct contact with the patient or contaminated equipment is anticipated during transport. In this case, one person should wear the appropriate PPE per CDC COVID-19 guidance, and, ideally, be accompanied by an additional member of the transport team who is not wearing a gown and gloves. The person without gloves and gown can interact with the environment. Prior to transport, the PPE clad person should perform hand hygiene and don a fresh gown and gloves to reduce potential contamination of environmental surfaces.

When performing procedures on patients with known or suspected COVID-19 infection:

  • Do not bring the patient to the holding or PACU areas. A designated OR should be allocated and signs posted on the doors to minimize staff exposure.
  • If general anesthesia is not required, the patient should continue to wear the surgical mask.
  • If general anesthesia is used:
    • Place a HEPA filter between the Y-piece of the breathing circuit and the patient's mask, endotracheal tube or laryngeal mask airway.
    • Alternatively, for pediatric patients or other patients in whom the additional dead space or weight of the filter may be problematic, the HEPA filter should be placed on the expiratory end of the corrugated breathing circuit before expired gas enters the anesthesia machine.
    • The gas sampling tubing should also be protected by a HEPA filter, and gases exiting the gas analyzer should be scavenged and not allowed to return to the room air.
  • During laryngoscopy and intubation:
    • Double gloves will enable one to shed the outer gloves after intubation and minimize subsequent environmental contamination.
    • Designate the most experienced anesthesia professional available to perform intubation, if possible.
    • Avoid awake fiberoptic intubation unless specifically indicated. Droplets containing viral pathogens may become aerosolized during this procedure. Aerosolization generates smaller liquid particles that may become suspended in air currents, traverse filtration barriers, and inspired.
    • Consider a rapid sequence induction (RSI) in order to avoid manual ventilation of patient’s lungs and potential aerosolization. If manual ventilation is required, apply small tidal volumes.
    • After removing protective equipment, avoid touching your hair or face and perform hand hygiene.
  • If available, use a closed suction system during airway suctioning. Closed suctioning systems may only be available in the critical care setting.
  • Consider disposable covers (e.g., plastic sheets for surfaces, long ultrasound probe sheath covers) to reduce droplet and contact contamination of equipment and other environmental surfaces.
  • The patient should be recovered in the operating room or transferred to an airborne infection isolation room.
  • After the patient has left the operating room, leave as much time as possible before subsequent patient care (for the removal of airborne infectious contamination). The length of time depends on the number of air exchanges per hour in the specific room or space. See this CDC reference for more detailed guidance.
  • After the case, clean and disinfect high-touch surfaces on the anesthesia machine and anesthesia work area with an EPA-approved hospital disinfectant.
  • If devices such as point-of-care ultrasound are used:
    • A long sheath cover of the ultrasound unit and cable should be used to minimize contamination of the equipment.
    • Non-essential parts of the ultrasound cart may best be covered with drapes to minimize droplet exposure.

DisclaimerThese links are being provided as a convenience and for informational purposes only; they do not constitute an endorsement or an approval by the Stanford University School of Medicine of any of the products, services or opinions of the corporation or organization or individual. The Stanford University School of Medicine bears no responsibility for the accuracy, legality or content of the external site or for that of subsequent links. Please contact the external site for answers to questions regarding their content.